Process equipment that holds pressure must be protected against overpressure, and Roben Manufacturing integrates the safety equipment that provides that protection into the systems we build. Relief valves, rupture discs, and their connections are designed into the vessels and piping so the equipment is protected to code and personnel are kept safe.

Overpressure protection is not optional — it is a code requirement and a fundamental safety obligation. We design the relief connections and integrate the safety devices as part of our complete-system projects so that protection is built in, not bolted on as an afterthought.

Overpressure Protection Built Into the System

Every pressure vessel must be protected against exceeding its maximum allowable working pressure, and the code requires pressure-relief devices sized for the worst-case overpressure scenario. We design the relief connections — the nozzles and piping that carry relieving flow — into the vessels and integrate relief valves, rupture discs, or combinations of the two as the service requires.

Sizing the relief path correctly is essential: an undersized relief device cannot protect the vessel, while the relief piping must carry the relieving flow without excessive back pressure. We design the relief nozzles and connections to suit the selected devices and the relieving conditions, coordinating with the overall vessel design.

Rupture discs, relief valves, and other safety devices each have their place. Relief valves reclose after relieving, rupture discs provide fast, full-bore relief and isolation from the process, and the two are sometimes combined. We integrate the appropriate devices and their connections so the protection scheme matches the hazard.

By designing safety equipment into the system from the start, we ensure the relief connections are properly located, sized, and reinforced as part of the vessel's code construction. The integrated system arrives with its overpressure protection in place and documented, ready for the safe operation the code and good practice demand.

Why Choose Roben Manufacturing

  • Code-required protection designed in. Relief connections and devices are designed into the vessels and piping to meet code overpressure requirements.
  • Correctly sized relief paths. Relief nozzles and connections are sized for the relieving flow and the selected devices.
  • Right device for the hazard. Relief valves, rupture discs, or combinations are integrated to match the protection scheme to the hazard.
  • Reinforced, located connections. Relief connections are located and reinforced as part of the vessel's code construction.
  • Protection in place at delivery. The integrated system arrives with overpressure protection installed and documented.

Key Features & Capabilities

  • Pressure-relief connection design into vessels and piping
  • Relief valve integration
  • Rupture disc integration
  • Combined relief-valve and rupture-disc arrangements
  • Relief-path sizing for relieving flow and back pressure
  • Relief nozzle location and reinforcement to code
  • Coordination of safety devices with the vessel design
  • Protection scheme matched to the overpressure hazard
  • Integration within complete process systems
  • Documentation of the overpressure protection

Applications & Industries Served

  • Overpressure protection for pressure vessels and reactors
  • Relief systems for jacketed and heated equipment
  • Process skids requiring integrated safety devices
  • Corrosive-service relief with appropriate materials
  • Systems handling reactive or volatile media
  • Plant systems requiring code-compliant relief

Codes, Standards & Quality Assurance

Roben Manufacturing fabricates under a controlled quality system and holds the ASME U Certificate of Authorization, with registration through the National Board of Boiler and Pressure Vessel Inspectors. Every applicable project is supported by material test reports, qualified welding procedures, nondestructive examination records, and complete documentation.

Relevant standards and resources include: ASME Boiler and Pressure Vessel Certification; National Board of Boiler and Pressure Vessel Inspectors.

Frequently Asked Questions

Yes. We integrate pressure-relief and safety equipment — relief valves, rupture discs, and their connections — into the vessels and systems we build.
The code requires every pressure vessel to be protected against exceeding its maximum allowable working pressure, using relief devices sized for the worst-case overpressure scenario.
Relief nozzles and connections are sized for the relieving flow so the device can protect the vessel and the relief piping carries the flow without excessive back pressure.
A relief valve recloses after relieving, while a rupture disc provides fast, full-bore relief and isolates the device from the process. The two are sometimes combined.
Yes. Relief nozzles are located and reinforced as part of the vessel's code construction, designed to suit the selected relief devices.
The device — relief valve, rupture disc, or combination — is selected to match the overpressure hazard and the process conditions of the equipment.
Yes. The relief connections and devices can be specified in materials appropriate to corrosive service, matched to the vessel.
Yes. The integrated system arrives with its overpressure protection installed and documented, ready for safe operation.
Yes. Designing safety equipment in from the start ensures the relief connections are properly located, sized, and reinforced rather than added as an afterthought.
Provide your vessel and process conditions and any relief requirements. Call (732) 364-6000 or email sales@robenmfg.com.

Request a Quote on This Project

Contact Roben Mfg., Inc. to discuss your project specifications, timeline, and material requirements.

📞 (732) 364-6000 sales@robenmfg.com 📍 760 Vassar Ave, Lakewood, NJ 08701
Request a Quote